Design and Construction of an Electronic Heart Beat Monitor.

The design of safe monitors of physiological events in humans is of paramount importance in the field of medical electronics, and this report describes the development of a safe computer-based heart beat monitor for hospital use. The heart beats are detected by passing light through a finger into a...

Popoln opis

Shranjeno v:
Bibliografske podrobnosti
Glavni avtor: Oladunjoye, Olunu Akintunde
Drugi avtorji: Kehinde, L. O.
Format: Thesis
Jezik:angleščina
Izdano: Obafemi Awolowo University 2014
Teme:
Online dostop:http://localhost:8080/xmlui/handle/123456789/3150
Oznake: Označite
Brez oznak, prvi označite!
_version_ 1810764577460191232
author Oladunjoye, Olunu Akintunde
author2 Kehinde, L. O.
author_facet Kehinde, L. O.
Oladunjoye, Olunu Akintunde
author_sort Oladunjoye, Olunu Akintunde
collection DSpace
description The design of safe monitors of physiological events in humans is of paramount importance in the field of medical electronics, and this report describes the development of a safe computer-based heart beat monitor for hospital use. The heart beats are detected by passing light through a finger into a photo-diode. Each time the heart beats, it pumps blood round the body and this causes the density of many parts of the body to vary, particularly the finger tips. By passing light through the finger tip onto a photodiode, this variation in density is converted into electrical signal that varies with the heart beat. The output of the photodiode is amplified in detection and amplification circuit to produce a CMOS compatible pulse each time the heart beats. An electronic method that does not employ a computer is first designed as a basis for comparison with the computer based method. In this method the time interval between successive three heart beats is measured and on the basis of the measured interval, the heart rate is computed by employing digital division method. This method, like others employing digital division method in computing the heart rate, has a reliable narrow operating frequency from 40 to 200 BPM, and a resolution of IBPM. Its main problem arises from truncation error. In the computer based method, the heart beat detection and amplification circuit is interfaced with a digital micro-computer. The microcomputer is programmed to measure the time interval between successive three heart beats, to compute the heart beat rate and to provide both graphical and numerical indications of the heart beat rate. This method has a wide operating range (10 to 10920 BPM), and a resolution less than BPM.
format Thesis
id oai:ir.oauife.edu.ng:123456789-3150-
institution My University
language English
publishDate 2014
publisher Obafemi Awolowo University
record_format dspace
spelling oai:ir.oauife.edu.ng:123456789-3150-2023-05-13T11:12:51Z Design and Construction of an Electronic Heart Beat Monitor. Oladunjoye, Olunu Akintunde Kehinde, L. O. Electronic heartbeat monitor photodiode The design of safe monitors of physiological events in humans is of paramount importance in the field of medical electronics, and this report describes the development of a safe computer-based heart beat monitor for hospital use. The heart beats are detected by passing light through a finger into a photo-diode. Each time the heart beats, it pumps blood round the body and this causes the density of many parts of the body to vary, particularly the finger tips. By passing light through the finger tip onto a photodiode, this variation in density is converted into electrical signal that varies with the heart beat. The output of the photodiode is amplified in detection and amplification circuit to produce a CMOS compatible pulse each time the heart beats. An electronic method that does not employ a computer is first designed as a basis for comparison with the computer based method. In this method the time interval between successive three heart beats is measured and on the basis of the measured interval, the heart rate is computed by employing digital division method. This method, like others employing digital division method in computing the heart rate, has a reliable narrow operating frequency from 40 to 200 BPM, and a resolution of IBPM. Its main problem arises from truncation error. In the computer based method, the heart beat detection and amplification circuit is interfaced with a digital micro-computer. The microcomputer is programmed to measure the time interval between successive three heart beats, to compute the heart beat rate and to provide both graphical and numerical indications of the heart beat rate. This method has a wide operating range (10 to 10920 BPM), and a resolution less than BPM. 2014-04-02T09:30:05Z 2018-10-27T12:25:50Z 2014-04-02T09:30:05Z 2018-10-27T12:25:50Z 1986 Thesis APA http://localhost:8080/xmlui/handle/123456789/3150 en PDF application/pdf Obafemi Awolowo University
spellingShingle Electronic heartbeat monitor
photodiode
Oladunjoye, Olunu Akintunde
Design and Construction of an Electronic Heart Beat Monitor.
title Design and Construction of an Electronic Heart Beat Monitor.
title_full Design and Construction of an Electronic Heart Beat Monitor.
title_fullStr Design and Construction of an Electronic Heart Beat Monitor.
title_full_unstemmed Design and Construction of an Electronic Heart Beat Monitor.
title_short Design and Construction of an Electronic Heart Beat Monitor.
title_sort design and construction of an electronic heart beat monitor
topic Electronic heartbeat monitor
photodiode
url http://localhost:8080/xmlui/handle/123456789/3150
work_keys_str_mv AT oladunjoyeolunuakintunde designandconstructionofanelectronicheartbeatmonitor