Study of Safe Separation Distances between Rural Wells and Neighbouring Soak-Away Systems
It is becoming increasingly common for educated Nigerians to build houses in rural and semi-urban areas of the country. The plan of a typical modern house includes construction of a septic tank and soakaway for disposal of wastewaters. Very often, a well is dug on the same plot of land for supply of...
Sábháilte in:
| Príomhchruthaitheoir: | |
|---|---|
| Formáid: | Online |
| Teanga: | Béarla |
| Foilsithe / Cruthaithe: |
The Faculty of Agriculture Obafemi Awolowo University, Ile-Ife, Nigeria.
2020
|
| Ábhair: | |
| Rochtain ar líne: | https://ija.oauife.edu.ng/index.php/ija/article/view/300 |
| Clibeanna: |
Cuir clib leis
Níl clibeanna ann, Bí ar an gcéad duine le clib a chur leis an taifead seo!
|
| Achoimre: | It is becoming increasingly common for educated Nigerians to build houses in rural and semi-urban areas of the country. The plan of a typical modern house includes construction of a septic tank and soakaway for disposal of wastewaters. Very often, a well is dug on the same plot of land for supply of water in lieu of tap water supply.
The study reported in this paper shows that in a silty sand soil, the safe separation is about 14 meters, |
|---|