Study of Safe Separation Distances between Rural Wells and Neighbouring Soak-Away Systems
It is becoming increasingly common for educated Nigerians to build houses in rural and semi-urban areas of the country. The plan of a typical modern house includes construction of a septic tank and soakaway for disposal of wastewaters. Very often, a well is dug on the same plot of land for supply of...
Kaydedildi:
| Yazar: | |
|---|---|
| Materyal Türü: | Online |
| Dil: | İngilizce |
| Baskı/Yayın Bilgisi: |
The Faculty of Agriculture Obafemi Awolowo University, Ile-Ife, Nigeria.
2020
|
| Konular: | |
| Online Erişim: | https://ija.oauife.edu.ng/index.php/ija/article/view/300 |
| Etiketler: |
Etiketle
Etiket eklenmemiş, İlk siz ekleyin!
|
| Özet: | It is becoming increasingly common for educated Nigerians to build houses in rural and semi-urban areas of the country. The plan of a typical modern house includes construction of a septic tank and soakaway for disposal of wastewaters. Very often, a well is dug on the same plot of land for supply of water in lieu of tap water supply.
The study reported in this paper shows that in a silty sand soil, the safe separation is about 14 meters, |
|---|